電纜橋架的支、吊架的配置要求
水平敷設時,支架間距一般不應大于2000mm。
When laying horizontally, the spacing between supports should generally not exceed 2000mm.
彎頭附近應增設支架,彎頭半徑小于300mm時,應在彎頭兩端各300-600mm處設置一個支架。
A bracket should be added near the elbow. When the radius of the elbow is less than 300mm, a bracket should be set at 300-600mm at each end of the elbow.

垂直單層敷設時,支架間距不應超過2000mm。多層時應通過計算確定。
When laying vertically in a single layer, the spacing between supports should not exceed 2000mm. When there are multiple layers, they should be determined through calculation.
立柱應與托盤、梯架層間距離相適應,以便多層布置。
The distance between the columns and the pallets and ladder layers should be suitable for multi-layer layout.
吊桿不應使用小于10mm的圓鋼,應有防晃措施,端部應有固定措施。
The suspension rod should not use round steel smaller than 10mm, and anti sway measures should be taken. The end should have fixing measures.
豎井內敷設時,每3-5層設置一個承重支架,不應安裝在固定電纜的橫擔上。
When laying in the vertical shaft, a load-bearing bracket should be installed every 3-5 layers and should not be installed on the cross arm of the fixed cable.
固定支架與預埋件焊接時,焊縫應滿足質量要求,長度不應少于25mm。
When welding fixed brackets and embedded parts, the weld seam should meet quality requirements and the length should not be less than 25mm.
使用膨脹螺栓時應符合相關標準規定。
The use of expansion bolts should comply with relevant standards and regulations.
支架安裝應垂直、無明顯扭曲,高度誤差不超過公差要求。
The bracket installation should be vertical, without obvious distortion, and the height error should not exceed the tolerance requirements.
支架的設計和安裝應滿足其強度、剛度和穩定性的要求。
The design and installation of the bracket should meet its requirements for strength, stiffness, and stability.
主體鋼結構上不得焊接支、吊架,應征得結構許可。
Welding of supports and hangers is not allowed on the main steel structure, and a structural professional permit must be obtained.
支、吊架的設計應根據托盤、梯架的規格、層數、跨距等條件進行配置,并滿足載荷要求。
The design of supports and hangers should be configured according to the specifications, number of layers, span, and other conditions of pallets and ladders, and meet the load requirements.
托臂的開孔位置應協調層間距離的要求。立柱可預留可調節的長孔。
The opening position of the support arm should be coordinated with the requirements of interlayer distance. The column can reserve adjustable long holes.
支、吊架的規格和型號應在滿足載荷條件下,根據項目的實際情況選擇。
The specifications and models of supports and hangers should be selected according to the actual situation of the project while meeting the load conditions.
金屬支、吊架應進行防腐處理,特別是戶外和潮濕環境的。
Metal supports and hangers should undergo anti-corrosion treatment, especially in outdoor and humid environments.
支、吊架的設計計算和試驗應驗證其滿足強度、剛度和穩定性要求。
The design calculation and testing of supports and hangers should verify that they meet the requirements of strength, stiffness, and stability.
下一篇:電纜橋架安裝規范標準
相關文章 / Recommended news
- 濟南廠房福音!大跨距橋架破解3大痛點,加強筋加,安裝省一半錢
- 山東工程人警惕!橋架敷線踩這坑必返工,監理當場叫停,國標早有明確規定
- 濟南人避坑!橋架≠線槽,90%工程人都搞混,一字之差差千里
- 避坑指南!山東電纜橋架規格別瞎選,偏大浪費偏小隱患大,國標早就定好了
- 濟南人必看!鋁合金電纜橋架選對厚度,耐用又省心,90%的人選錯踩坑
- 山東人必看!電纜橋架不是“鐵架子”,藏著建筑用電的密碼,90%的人都不懂
- 800kg/m抗壓!濟南電纜橋架,破解3大工程痛點,工期省30%
- 3種類型+98%散熱!山東電纜橋架,選對不踩坑,布線效率翻倍
- 2類核心支架!濟南電纜橋架,抗震承重雙達標
- 別再混淆!山東電纜橋架vs線槽,6大核心區別一文分清
陽極氧化鋁合金橋架
托盤式電纜橋架
梯式電纜橋架
梯式不銹鋼電纜橋架
深灰色金屬防火電纜橋架